| Subject: | ghosts in the starter |
| From: | ray hale |
| Date: | Tue, 05 Mar 96 09:35:43 EST |
For the last year or so, I've had the following problem with my '66
(converted to 12 v): whenever it's driven long distances (like Fla to
N.C.) the starter fails. I have to crawl underneath with the mallet
and smack it a couple times and/or goose the solenoid with the
screwdriver. I've done this in heavy traffic, in the rain, and on
lonely mountain backroads (gee, I wonder when they'll find me). Now
that the motor is out again I'm determined to fix this.
I pulled the starter and took off the end cap. An honest handful of
rust fell out and then even more when I banged the unit on the
workbench. I disassembled further and sanded the armature, checked
the brushes, and sprayed the whole thing down with tuner cleaner. Put
it back together and took it down to the local electrical shop where
they bench tested it and gave it their blessings.
Next, I crawled under and inspected the wiring. The ass end of the
wire coming from the ignition switch has been replaced and the it
appears to be two sizes too small in gauge. I'll run a new wire all
the way. The ground cable to the battery is newish but the ends need
cleaning.
Am I missing anything else?
Oh yeah, my apologies to the list for my error on mileage when I
posted re: GEX motor problems. The clock is at 5k, not 5000k, as Joel
noticed and pointed out to me. Oops!! I do know a guy with 1000k on
his Mercedes sports and another with 1000k on a Moto Guzzi!! Maybe
someday.
RayHave something to add on this topic today? Revive this thread in the forum »