| Subject: | Re: halogen wisdom please |
| Date: | Sun, 19 Jan 1997 04:09:48 -0500 (EST) |
In a message dated 97-01-18 20:11:43 EST, jdiebolt@up.net (Jeff Diebolt) writes: > Why won't it work? Remember the purpose of a fuse is to protect the wiring > and equipment in the circuit. If the 100w bulb draws 7.6 amps it is below > the rated current carrying capacity of the wire. Also I ran 140w bulbs in > my 72 bus and never blew a fuse or wire and didn't have unusually short > bulb life. My advice is go ahead and use them. IMHO > At 10:18 PM 1/17/97 -0600, kenneth d lewis wrote: > >Sean; > >When it came time to replace one of mine I was wondering the same thing, > >"Will my wiring handle almost twice the current?". I doubt it. >> Don't do it. The fuse is there to protect against electrical shorts only. Often fuses are rated for 5 time the current draw of the protected circuit. This does not mean that the circuit can safely handle 5 times the current. Specificallly, others on this list have installed high wattage bulbs in 86-91 Vanagon headlights and have toasted the wiring at the back side of the headlight connector. Regards, Jim Davis
Have something to add on this topic today? Revive this thread in the forum »