You might want to consider putting in a relay, even if the wiring will handle the load. With a relay you will get the maximum output from the lights. Also, your headlight switch will probably last longer because you'll eliminate the possibility of arcing. Michael Stocker --- On Sat, 18 Jan 1997 19:10:43 -0600 Jeff Diebolt <jdiebolt@up.net> wrote: >Why won't it work? Remember the purpose of a fuse is to protect the wiring >and equipment in the circuit. If the 100w bulb draws 7.6 amps it is below >the rated current carrying capacity of the wire. Also I ran 140w bulbs in >my 72 bus and never blew a fuse or wire and didn't have unusually short >bulb life. My advice is go ahead and use them. IMHO >At 10:18 PM 1/17/97 -0600, kenneth d lewis wrote: >>Sean; >>When it came time to replace one of mine I was wondering the same thing, >>"Will my wiring handle almost twice the current?". I doubt it. >>Good Luck >>Ken Lewis >>kdlewis@juno.com >>86 VW crewcab >>85 VW Vanagon GL >>60 356 coupe >> >>On Wed, 15 Jan 1997 21:46:30 -0600 Sean Bartnik <sbart7kb@www.mwc.edu> >>writes: >>, the 55W bulb draws 4.2 ampswhile the 100W bulb draws 7.6 amps. >>>Anyway, don't forget the original question :) . Can I safely put >>>100W >>>H3 bulbs in a light made for 55W H3 bulbs? >>> >>>Thanks all, >>>Sean >>> >> >> > > Greetings from Michigan's Upper Peninsula > Jeff & Jean-Marie Diebolt > mailto:jdiebolt@up.net -----------------End of Original Message----------------- ___________________________________________ Michael Stocker <mdstockr@neo.lrun.com> North Canton, Ohio, USA Date: 1/18/97 Time: 8:14:20 PM ___________________________________________
Have something to add on this topic today? Revive this thread in the forum »