| Subject: | RE: Rack am Ruined |
| From: | Tom Brunson |
| Date: | Thu, 3 Jul 97 19:12:29 UT |
When I replaced the Rack on my '87 it came with severe warnings that if the old one failed due to metal filings & junk from a bad pump that the warranty would be void if you didn't replace the pump. It also stressed the need to purge the system and replace the filter in the P/S resevoir. Even so, I doubt if the new rack would fail in two weeks even with crud in the system - I'd bet you had damaged seals or mating surfaces in the rack when you got it. TFE seal rings are not at all forgiving about damage. I got my rebuilt rack last year through Austin Vee Dub - with the rebuilder they used (don't know who) it cost about $400 + core. So far the new one has been great. Tom Brunson >Hello; After replacing the rack and pinion in my 87 G, two weeks ago, I >have been losing ATF from the p/s reservoir at a rate of about a cup a day. >I parked the van over a sheet of cardboard overnight and found that the leak >was from both ends of the rack where the rubber bellows slip over the >housing. Did I get a bum rack and pinion? or could some debris in the >system, which I didn't flush, take out the new seals. Has anyone else had >this problem? This is the rack that cost me $1000. hadn't even lasted one >month. No other symptoms to report, Dexron oil ATF Castrol no rude noises, >no excessive heat or any thing else Puzzled Larry Carter ..