| Subject: | Re: HELP! MY RADIATOR FAN QUIT! |
| From: | Tyrone & Marilyn Greene |
| Date: | Thu, 2 Jul 1998 05:39:27 -0400 |
Scott DeSanti wrote: > > Oh Wise Listmembers, > > I have searched the archives and cannot find any previous incident of > the fault my 86 Weekender is suffering. The radiator fan simply won't come > on. There's 12v getting to the positive connector on the back of the fan but > nothing happens. I ohmed out the big green resistor but my meter doesn't read > low enough to get an acurate measure....but it's definitely not open. If I > connect a wire from the negative fan connector to ground....it runs... I > cleaned the ground terminals behind the fuse block, too. I don't have a > manual so I can't trace the rest of the circuit. I believe the ground for the > motor is routed somewhere besides straight to ground. Any and all help is > greatly appreciated. > > Scott De Santi > 86 Weekender Bently [p.97.82] shows that after the "RAD. COOL FAN" there should be a BROWN wire going to ground "behind upper air intake flap (near radiator)". Tyrone Big Pine Key, FL 87 GL Syncro etc.....