| Subject: | Re: Power Window Regulator Crunch!! |
| From: | Dr. Rainer Woitok |
| Date: | Thu, 16 Jul 1998 11:57:07 +0200 |
Volks, On Thu, 1998-07-16 03:52:56 EDT, Erlaz@aol.com wrote: > Has anyone had a problem with their power window regulators. Both of mine are > stuck in the same week. They make a crunching sound as they wind up or down. > Took motor off and they run fine, switches are OK. Might as well be mechanical alignment. Loosen (but don't remove) the two screws which attach the lifter mechanism to the window. Roll the window up and down (or down and up :-) a few times. If things improve, fasten the screws without again spoiling the alignment. I hope this helps. Sincerely Rainer ---------------------------------------------------------------------- | Rainer M Woitok | Phone: (+49-9131) 85-7811, -7031 | | Regionales Rechenzentrum | | | Friedrich-Alexander-Universitaet | Fax : (+49-9131) 30 29 41 | | Martens-Strasse 1 | Telex: d 629 755 tf erl | | D-91058 Erlangen | | | Germany | Mail: Woitok@RRZE.Uni-Erlangen.DE | ----------------------------------------------------------------------