Mark, Yes, I agree. With the setup you described, one could use a stronger than 40 amp relay without overloading the thin stock trigger wires, if one desires. I wonder if everyone understands what you described. I think it's a good idea, if installed correctly. Harald '90 westy Mark wrote: > There is of course a finite limit to the trigger circuits fan-out > capability but I have no idea what it is. I have had this concern myself > when adding a second battery. A simple way to avoid increasing the > current drain on the trigger circuit is to not use the trigger circuit > for the added relay. Just connect a wire from the high current output of > the stock relay to the trigger circuit input on the second relay. This > small added load to the stock relay would be very minor and this method > helps isolate the stock wiring from the high current auxiliary battery > wiring. > > Mark Drillock > > harald_nancy wrote: > > > I am mostly concerned about the relay trigger > > circuit. I would not want to overload it, with > > a too heavy "industrial" type of relay. > > Personally, I would rather that the breaker > > shuts off once in awhile than risk overloading > > the trigger wires with too big a relay. > > And as you once said, a deep > > cycle should not be charged too fast anyway. > > My main concern is not to damage anything that is stock, > > in this case, the wiring harness with the trigger wires.