| Subject: | Re: Source for water tank level sensor |
| From: | David Beierl |
| Date: | Fri, 14 May 1999 12:32:10 -0400 |
At 13:11 5/14/99 -0300, you wrote: >OK I just took the Ohm meter to my water level stick and when the >float is at the top, I get no resistance (closed circuit), about 1 inch >down I hear the click and the ohm meter reads about 250K as I >move the float all the way down to within one inch of the bottom, >then I get another click and the Ohm meter goes to 350K (nearly >infinity - open circuit). If that is of any help to anybody. Yes, it is. We are hot on the trail of this thing, and I understand the circuitry in the LED panel. If anyone else would care to ohm out their sender and send me the results (specifying also how your lights behave) I would appreciate it. I will publish the results. >I should add that my LEDs also do not read properly and I have >taken the wand out of the van, I do not know if the wand or the >LEDs are bad. I'll try the Bentley 97.30 analysis. Malcolm Malcolm, don't bother -- 97.30 is for the older method with electrodes in the tank. But please do tell me what your lights actually do with the float in various positions. I have good hopes of developing a systematic fix. david David Beierl - dbeierl@ibm.net
Have something to add on this topic today? Revive this thread in the forum »