| Subject: | Re: Dometic Fridge Defrosting & Fuel Consumption |
| From: | David Beierl |
| Date: | Tue, 25 May 1999 11:01:24 -0400 |
At 09:39 5/25/99 -0400, sh@interlog.com wrote: >Just wondering if anyone else has experienced the icing up problem on the >coils. Seems to start after 2 days of use (on propane) regardless of >ambient weather conditions. It gets worse from there, and a major >defrosting (and/or chipping away of the buildup) is required after 3-4 days. These coils (however powered) will freeze moisture out of the air just like any non-self-defrosting reefer. But to get that much in four days is strange; they can't freeze out moisture that isn't there. Are you keeping pans of hot water there for safekeeping? <g> Somehow water vapor is getting in there -- no door gasket? Mischievous demons? My guess is that you have considerable air leaks at top and bottom of the door, which could set up a convective loop and pull air through. Hey! You've just invented the dehumidifier, door-to-door service and flooded basements our specialty! >Also wondering if propane consumption is the same (since the flame is >always on), regardless of the ambient temperatures or thermostat setting. Nope. It uses lots more gas in hot weather. About a couple weeks per tank in New England summertime, vs a month or more in cold weather. The flame gets much bigger when it's actually trying to cool. david David Beierl - dbeierl@ibm.net