Hi Steve,
The most trouble some is the one under and to the front of the coil that
has a ground strap that goes over to the left head. This is a critical
ground on both ends for the digifant 86 -91. the one inside next to the ecu
rarely gives problems.
On a digijet (83.5-85), be sure your ecu is good and tight in the
mounting frame and the frame is attached well to the van body. The grounds
to the body in front of the coil are important also.
Darrell
----- Original Message -----
From: Steven X. Schwenk <Steve@Schwenk-Law.com>
To: <vanagon@GERRY.VANAGON.COM>
Sent: Thursday, June 17, 1999 9:22 PM
Subject: Send in the Grounds...
> Where are the main ground connections that if loose may
> affect FI performance?
> I need a little help due to time.
> Thanks
> steve