| Subject: | Re: 90 Carat 50 amp fuse for A/C: Substitution Possiblities |
| From: | Davidson |
| Date: | Wed, 24 Nov 1999 07:20:25 -0800 |
Mark, after you find the fuse and put it in, don't just close up and start driving again. Run the engine with the A/C on high setting and check the wires and connectors near the 50 amp fuse.... they are notorious for getting way hot... and even causing fires. Mine were hot enough that I couldn't hold them with my bare hands for more than a second.... If they are hot try cleaning up the connectors with contact cleaner for the hot wires. I did this and pasted them all with anti-corrosion grease (GB brand?) that also improves the conductivity. I also did this to the contacts (male and female) on the relays. This cooled my A/C wires and relays down to a safe level. If they are still hot, then try replacing connectors. Good Luck Bill 90 Westy Syncro -----Original Message----- From: Mark B. Magee <condor2@FLASH.NET> To: vanagon@GERRY.VANAGON.COM <vanagon@GERRY.VANAGON.COM> Date: Wednesday, November 24, 1999 5:38 AM Subject: 90 Carat 50 amp fuse for A/C: Substitution Possiblities >Volks, >With help of Listees (Thanks Joel) I have determined my A/C's S0 fuse >has blown. It is a strange fuse, a straight piece of thin lead and is >not readily availiable apparently. My question to the List is this, can >I replace this fuse with any other 12V 50 Amp fuse? Or is this fuse >something special, such as a Slow Blow. I would think this fuse would be >fast acting as most automotive fuses are. >Any help/feedback appreciated >Regards >Mark Magee 90 Carat >Kemah TX USA 87 GL >John 14:6 >